Home > Product > UC System for Tram

        UC System for Tram

        S545V19-K8-A

        Applications:Tram,Marine charger,Power compensator

        Characteristics:Customized system solution according to the voltage and energy requirements of tram operation

        021-50802888
        Please call for further information
        Product catalogue

        Summary

        Characteristics

        Customized system solution according to the voltage and energy requirements of tram operation

        High power and high energy, duel operation mode including "opportunity charging" and " terminal charging"

        System adapts to contacted network, mixed network, contactless network operation conditions

        Working temperature window:-25~55℃

        System is designed with multiple level protection, safe and reliable

        CMS can monitor the voltage, temperature, etc of each capacitor and automatically balance the voltage difference

        Applications

        Tram Marine charger

        Power compensator

        Other high power and high energy applications

        See the product catalogue for more information

        Dimension

        Picture of system S545V19-K8-A

        Features

        Part Number S545V19-K8-A
        Basic Module MUCK24V2870
        Module Connection Type 24 series
        Nominal Capacitance(F) 583
        Operating Voltage Window(V) 410~547
        Surge Voltage(V) 605
        Stored Energy (kWh) 9.5
        Standard Charge Current (A) 300
        Standard Discharge Current (A) ≤300
        Maximum Charge/Discharge Current(<20s) (A) 510
        Operating Temperature(oC) -25~55(QC/T 741-2014)
        -15~55(140A)
        Storage Temperature (oC) -30~+65
        Protection Level IP65(Except inlet and outlet)
        Electric Property Overvoltage, overcurrent, overheat, overload, short circuit, DC leakage protection, etc
        Capacitor Management System Automatic balance, voltage monitor, temperature monitor, DC leakage monitor, etc
        Cooling Mode Air cooling
        Communication Interface CAN
        Size(mm) 1950*1170*645
        Weight(kg) 1000

        Method & Notice

        Test conditions

        Ambient temperature: 25±5℃

        Relative humidity: 25%~85%

        Ambient pressure: 86~106kPa

        Standards and Conformity

        IEC 61373-2010 Railway applications--Rolling stock equipment--Shock and vibration tests

        GB 4208-2008 Degrees of protection provided by enclosure (IP code)

        EN 60077-1 Railway applications--Electric equipment for rolling stock Part 1: General service conditions and general rules

        EN 50124-1 Railway applications--Insulation coordination Part1: Basic requirements--Clearances and creepage distances for all electric and electronic equipment

        GB/T 24338.4 Railway applications-Electromagnetic compatibility

        QC/T 741-2014 Ultra-capacitor for electric vehicles

        Operating requirements

        System should be placed vertically upward during operation

        As a high voltage device, the system shall not be used, disassembled or maintained by non -professionals.

        When connecting the system to external circuit, the circuit switch must be cut off first, otherwise there would be danger of high-voltage shock

        Before operating the system, connect communication cables to vehicle system correctly, and make sure the positive and negative polarity of power supply and load

        Short-circuit and reverse connection of the system is strictly prohibited, cut off circuit and take safety measures once such cases happen

        Check each parameter on the human-computer interface(HMI) to ensure the voltage of each cell is between 2.85~3.8V and the maximum voltage difference shouldn’t be larger than 300mV

        Collision, strike, crush to the system case is strictly prohibited, forbid opening the box during operation, forbid contacting live part such as positive or negative terminal and power cables with any material

        Please stop charging when peculiar smell or abnormal noise is found during charging the system

        Abandoning used capacitor is strictly prohibited, please discharge capacitor to 0V before recycling

        Storage and transportation requirements

        Ambient temperature: -30~65℃

        Relative humidity: 0~95%

        Ambient pressure: 86~106kPa

        System should be placed vertically upward during storage and transportation

        Keep power interfaces protected in order to prevent collision, which may cause short circuit during the process of storage and transportation

        System must be charged to rated voltage before long term storage and transportation. Check cell voltage difference every 4 months, when cell voltage difference is<300mV and >50mV, balance system should be activated until the cell voltage difference drops to ≤40mV, when cell voltage difference is>300mV, child node or capacitor should be checked, replace the bad child node or cell if necessary

        When system is kept unused for longer than 1 year, it should be tested by Aowei before using.

        See the product catalogue for more information

        Copyright ? 2018 AOWEI TECHNOLOGY Shanghai ICP 05008425   |  Download  |  Disclaimer |  Map

        欧美亚洲另类在线高清